YOCL

BDM-17 Single Compression Armored Ex d Cable Gland

BDM-17 single compression armored metal cable gland, identified as a barrier type in the supplied product description, for hazardous-area cable entry.

  • Brass, nickel-plated brass, SS304 or SS316 bodies.
  • Deluge ingress protection; specified IP66 and IP68 (1 m, 1 h).
  • Metric and NPT for Ex d, Ex e and Ex t; G thread for Ex e and Ex t only.
  • 15 sizes with separate sheath and armor-orientation data.
  • Nylon washer and locknut as standard, except for NPT versions.
Produkt anfragen

Übersicht

The YOCL ELECTRIC BDM-17 Single Compression Armored Ex d Cable Gland provides armored cable entry with deluge ingress protection for moisture-exposed industrial environments, including marine applications. The supplied product description identifies it as a barrier type cable gland.

It is listed for steel wire armor, steel tape armor, braid armor and marine braided cable constructions. Lead-sheathed cable applications are described with an earth tag and earth plug. Thread selection determines which Ex applications are listed: metric and NPT threads for Ex d, Ex e and Ex t; G threads for Ex e and Ex t only.

Merkmale

  • Single compression construction: Armored metal cable gland with model-specific sheath and armor data.
  • Deluge ingress protection: Designed for environments exposed to moisture and water spray.
  • Tooth-shaped clamping cap: Provides a grip surface for handling during assembly.
  • Body material options: Brass, nickel-plated brass, SS304 and SS316.
  • Cable compatibility: Listed armored and lead-sheathed cable constructions, subject to size and accessory selection.

Technische Daten

Parameter Spezifikation
Model BDM-17
Type Single compression armored metal type; identified as barrier type in the supplied description
Body material options Brass; nickel-plated brass; SS304; SS316
Sealing material options Silicone rubber; neoprene; PTFE (Teflon); PA6
Operating temperature options −20 °C to +60 °C / −60 °C to +80 °C, depending on configuration
Supplied Ex marking Ex db IIC Gb; Ex eb IIC Gb; Ex tb IIIC Db, subject to thread configuration
Application designation II 2GD, as stated in the supplied specification
Ingress protection IP66; IP68 (1 m, 1 h)
Metric and NPT thread applications Ex d; Ex e; Ex t
BSP (G) thread applications Ex e; Ex t only
Approvals stated in supplied specification IECEx; ATEX; EAC (CUTR); CNEx
Standards listed in supplied specification IEC/EN 60079-0; IEC/EN 60079-1; IEC/EN 60079-31; IEC/EN 60529
Standard accessories Nylon washer and locknut, except for NPT versions
Optional accessories Earth tag; PVC shroud; serrated washer; red fibre washer; A/B putty compound
Lead-sheathed cable accessory condition Earth tag and earth plug, as stated in the supplied description

The temperature options are configuration-dependent. The supplied data does not map each option to a sealing material and does not provide certificate numbers. The G-thread option is not listed for Ex d use.

Abmessung

Sheath and Armor Data

Dimensions are in millimetres, except the NPT/G nominal thread sizes in inches. The strict less-than limits for A and the slash-separated armor values are retained from the supplied table.

Size Metric entry thread AG NPT/G nominal size (inch) Inner sheath A (mm) Outer sheath B (mm) Armor orientation 1 (mm) Armor orientation 2 (mm)
20A M20×1.5 1/2 <11 5.5–12 0.9/1.25 0/0.7
20B M20×1.5 1/2 <11 9.5–16 0.9/1.25 0/0.7
20C M20×1.5 1/2 <15 12.5–20.5 0.9/1.25 0/0.7
25B M25×1.5 3/4 <15 12.5–20.5 0.9/1.25 0/0.7
25C M25×1.5 3/4 <21 17–26 1.25/1.6 0/0.7
32B M32×1.5 1 <21 17–26 1.25/1.6 0/0.7
32C M32×1.5 1 <27 22–33 1.6/2 0/0.7
40B M40×1.5 1-1/4 <27 22–33 1.6/2 0/0.7
40C M40×1.5 1-1/4 <33 28–41 1.8/2.5 0/0.7
50B M50×1.5 1-1/2 <33 28–41 1.8/2.5 0/1.0
50C M50×1.5 1-1/2 <43 36–52.6 1.8/2.5 0/1.0
63B M63×1.5 2 <43 36–52.6 1.8/2.5 0/1.0
63C M63×1.5 2 <54.5 46–65 1.8/2.5 0/1.0
75B M75×1.5 2-1/2 <54.5 46–65 1.8/2.5 0/1.0
75C M75×1.5 2-1/2 <66 57–78 1.8/2.5 0/1.0

The armor values are listed by orientation; slash-separated entries are not rewritten as continuous min–max ranges. Select the compatible armor-ring orientation for the actual cable construction. The NPT/G column gives a nominal size; the actual thread standard and permitted Ex application must be specified separately.

Length Data

Size Body length L1 (mm) Entry thread length L (mm)
20A 70 16
20B 70 16
20C 81 16
25B 81 16
25C 91 16
32B 91 18
32C 96 18
40B 96 18
40C 107 18
50B 107 18
50C 132 18
63B 132 20
63C 145 20
75B 145 20
75C 154 20

L1 and L follow the source drawing: L1 is the body length beyond the entry thread and L is the entry thread length. No maximum external diameter D is supplied for this model.

Accessories and Ordering

Specify BDM-17 size, body material, actual thread standard and size, inner and outer sheath diameters, armor construction and required ring orientation. Include the required Ex application and operating temperature configuration.

For lead-sheathed cables, specify the earth tag and earth plug described for that application. Nylon washers and locknuts are standard except for NPT versions. PVC shrouds, serrated washers, red fibre washers and A/B putty compound are listed as optional accessories.

For a barrier configuration, specify the compatible compound system and its supply with the order. The supplied data does not define the compound formulation, curing procedure or installation torque; use the documentation for the delivered configuration.

Projektdetails

Felder mit * sind erforderlich.

Ihre Daten werden verwendet, um auf Ihre Anfrage zu antworten. Datenschutzhinweis