YOCL

YOCL ELECTRIC FJ6/JTS2 Multifunctional Distribution Terminal Blocks

FJ6/JTS2 multifunctional distribution terminal blocks for one-in/one-out or multiple-outlet wiring.

  • 14 complete model configurations.
  • 690 V; model-specific 150–400 A ratings.
  • Copper conductive block and insulating side plates.
  • Transparent top cover.
  • Incoming and output conductor ranges listed by model.
Inquire about this product

Overview

YOCL ELECTRIC FJ6/JTS2 multifunctional distribution terminal blocks use a copper conductive block with insulating side plates and a transparent top cover. The series includes one-in/one-out and one-in/multiple-out configurations, with separate conductor ranges and 150 A, 250 A, 300 A or 400 A ratings.

Features

  • Copper conductive block.
  • Insulating side plates on both sides.
  • Transparent top cover.
  • Complete wiring structures and conductor ranges identified by model.

Technical Specifications

Parameter Specification
Rated voltage 690 V
Conductive block Copper
Side construction Insulating side plates on both sides
Top cover Transparent

Model Specifications

Model Wiring structure Incoming range (mm²) Output range (mm²) Voltage (V) Current (A)
FJ6/JTS2-21mm-35/1×35 1 in 1 out 10-35 10-35 690 150
FJ6/JTS2-21mm-35/2×16 1 in 2 out 10-35 2.5-16 690 150
FJ6/JTS2-21mm-35/3×16 1 in 3 out 10-35 2.5-16 690 150
FJ6/JTS2-21mm-35/4×16 1 in 4 out 10-35 2.5-16 690 150
FJ6/JTS2-21mm-35/6×6 1 in 6 out 10-35 1.5-6 690 150
FJ6/JTS2-21mm-35/9×6 1 in 9 out 10-35 1.5-6 690 150
FJ6/JTS2-28mm-35/4×25 1 in 4 out 10-35 4–25 690 250
FJ6/JTS2-28mm-35/6×16 1 in 6 out 10-35 2.5-16 690 250
FJ6/JTS2-28mm-35/9×16 1 in 9 out 10-35 2.5-16 690 250
FJ6/JTS2-36mm-50/8×16 1 in 8 out 10-50 2.5-16 690 300
FJ6/JTS2-36mm-50/12×10 1 in 12 out 10-50 1.5-10 690 300
FJ6/JTS2-45mm-50/8×25 1 in 8 out 10-50 4–25 690 400
FJ6/JTS2-45mm-50/10×16 1 in 10 out 10-50 2.5-16 690 400
FJ6/JTS2-45mm-50/16×10 1 in 16 out 10-50 1.5-10 690 400

Selection Guide

Select the full model code together with wiring structure, conductor ranges and rated current. Dimensions embedded in model codes are retained as part of the identity and are not expanded into an unstated overall length, width or height.

Ordering Information

Specify the exact model, quantity and conductor requirements when requesting a quotation. Select a complete model row; ratings and connection capacities are not interchangeable between models.

Project details

Fields marked * are required.

Your details will be used to respond to your enquiry. Privacy notice