Metric threaded plastic vents
Metric · M5–M42
Languages Coming soon
Enclosure ventilation, specified for your assembly. Explore threaded and snap-on vents in PA66, stainless steel, brass and aluminum.

Compare the material, head style and mounting connection.

Metric · M5–M42

K01 · K02 · K03

Metric · G · NPT

Metric · M5–M20

Metric · M3–M12

M5 × 0.8 · M6 × 1

Metric · G · NPT

Metric · M5–M20

Metric · G · NPT

M5 × 0.8 · M6 × 1
No series matches this material. Select All materials to reset.
Two mounting forms. Different installation requirements.

Choose the exact thread form and pitch, then check thread engagement, head clearance and the sealing interface.
Metric, G and NPT availability varies by series.
Compare threaded series
K01, K02 and K03 use a PA66 body with snap-fit retention. Match the mating opening and panel thickness to the installation drawing.
Silicone O-ring · listed IP67 protection
Compare K-series dimensionsCatalogue values from the current product listings. Open a series for the complete dimensional table.
| Series | Connection | Listed protection | Minimum airflow values mL/min at 70 mbar |
|---|---|---|---|
| Threaded PA66 | Metric · M5–M42 | IP67 | 600–8,500 |
| Snap-on PA66 | K01 · K02 · K03 | IP67 | 800–1,500 |
| Stainless steel | Metric · G · NPT | IP68 | 200–8,500 |
| Flat hex stainless steel | Metric · M5–M20 | IP68 | 200–2,300 |
| Round slotted stainless steel | Metric · M3–M12 | IP68 | 200–800 |
| Standard slotted stainless steel | M5 × 0.8 · M6 × 1 | IP68 | 300 |
| Nickel-plated brass | Metric · G · NPT | IP68 | 200–18,000 |
| Flat hex nickel-plated brass | Metric · M5–M20 | IP68 | 200–2,300 |
| Aluminum alloy | Metric · G · NPT | IP68 | 200–8,500 |
| Slotted aluminum | M5 × 0.8 · M6 × 1 | IP68 | 200 |
Airflow ranges span different model rows, not the adjustment range of one vent. IP ratings are catalogue statements; verify the selected model’s test conditions and the assembled enclosure. IP68 immersion depth and duration are not supplied in these listings.
Start with the material, mounting interface and airflow you need.
Thread size alone does not determine a suitable vent. Send the mounting details and operating conditions together.
Prepare your specificationThread form, pitch, engagement and clearance; or the snap-in opening, panel thickness and retention requirements.
Compare values at the same pressure differential. These catalogue figures use 70 mbar; they do not define enclosure equalization time.
Share temperature, washdown, chemicals and outdoor exposure. Request the required metal grade, membrane and seal specification.
Confirm installation torque, sealing surfaces and the applicable ingress test before approving the enclosure design.
No. A cable gland provides a cable entry and sealing interface. A vent plug provides a ventilation path through a separate enclosure opening; it is not a cable entry.
No. The current PA66 threaded and snap-on listings state IP67. The metal listings state IP68. The rating of a component does not automatically establish the rating of the completed enclosure. Ask for model-specific test conditions.
Not reliably. Selection also needs the pressure-change requirement, temperature profile, leakage paths, available mounting position and the vent’s airflow characteristics. Provide these details for a technical review.
The same printed thread can have different overall lengths, thread lengths or airflow values. For example, the plastic M12 × 1.5-10 entries differ. Include the complete dimension row when ordering.
Send the series or model, material, thread or snap-fit dimensions, required airflow and pressure, application conditions, quantity and delivery destination. Include a drawing where available.