YOCL

YOCL ELECTRIC SV Branching Connector Sets

SV branching connector sets combine KE10 connectors with an earth wire and model-specific protective boxes.

  • Five complete assembly options.
  • Included earth wire: 16 mm², 35 cm, with cable lug.
  • Separate Al and Cu conductor ranges.
  • SV17 includes plastic boxes; SV17-G includes silicone boxes.
Inquire about this product

Overview

YOCL ELECTRIC SV branching connector sets combine KE10 connectors with a 16 mm² earth wire, 35 cm long, fitted with a cable lug. SV15, SV15.5 and SV50 provide different connector combinations. SV17 adds transparent plastic boxes, while SV17-G includes silicone boxes for its connectors. Each assembly retains its own conductor ranges and component list.

Features

  • Complete connector combinations identified by SV model.
  • 16 mm², 35 cm earth wire with cable lug in each listed set.
  • Transparent PC connector insulation.
  • Plastic-box and silicone-box assembly options.

Technical Specifications

Parameter Specification
Connector insulation PC
Colour listed in tables Transparent
Included earth wire 16 mm²; 35 cm; cable lug fitted
Connector type Branching

Set Contents

Model Included components
SV15 3×KE10.1 + 1×KE10.3 + earth wire with cable lug
SV15.5 4×KE10.1 + 1×KE10.3 + earth wire with cable lug
SV50 3×KE10.504 + 1×KE10.506 + earth wire with cable lug
SV17 3×KE10.1 + 1×KE10.3 + earth wire with cable lug + 3 transparent plastic KKK boxes
SV17-G 3×KE10.1 + 1×KE10.3 + earth wire with cable lug + 3 silicone boxes for KE10.1 + 1 silicone box for KE10.3

Model Specifications

Model Weight (kg) Al conductor range (mm²) Cu conductor range (mm²) Conductor diameter (mm) Core diameter (mm) Nominal cross-section (mm²) Listed maximum number of cores Torque (N·m)
SV15 0.28 10–35 1.5–25 1.7–9 1.7–9 1.5–35 4 10
SV15.5 0.33 10–35 1.5–25 1.7–9 1.7–9 1.5–35 5 10
SV50 0.3 10–50 2.5–35 2–10.2 2–10.2 2.5–50 4 10
SV17 0.35 10–35 1.5–25 1.7–9 1.7–9 1.5–35 4 10
SV17-G 0.48 10–35 1.5–25 1.7–9 1.7–9 1.5–35 4 10

Selection Guide

Select the complete set by the KE10 connector combination, conductor ranges and protective-box arrangement. The listed maximum number of cores is retained as a set specification; it is not a conductor-per-hole instruction.

Ordering Information

Specify the exact model, quantity and conductor requirements when requesting a quotation. Select a complete model row; ratings and connection capacities are not interchangeable between models.

Project details

Fields marked * are required.

Your details will be used to respond to your enquiry. Privacy notice