YOCL

LT2-8/LT4-8/LT3-12 Multi-Port Lever Connectors

YOCL ELECTRIC LT2-8, LT4-8 and LT3-12 multi-port lever connectors provide grouped cable entries in three connector layouts.

  • 250 V rated voltage; 32 A rated current
  • 0.5–4 mm² listed conductor cross-section
  • 11–12 mm stripping length
  • 3 listed model options
Inquire about this product

Overview

YOCL ELECTRIC LT2-8, LT4-8 and LT3-12 multi-port lever connectors provide grouped cable entries in three connector layouts. Their ratings are 250 V and 32 A, with a listed conductor cross-section range of 0.5–4 mm².

Features

  • Three grouped connector layouts with individual levers.
  • Catalogue P designations: LT2-8 2P, LT4-8 4P and LT3-12 3P.
  • 32 A rated current and 250 V rated voltage.
  • Shared 11–12 mm stripping length.

Technical Specifications

Parameter Specification
Models LT2-8, LT4-8, LT3-12
Rated voltage 250 V
Rated current 32 A
Conductor cross-section 0.5–4 mm²
Listed withstand voltage 4 kV
Ambient temperature −40 °C to +105 °C
Stripping length 11–12 mm
Plastic parts PC
Spring material S301
Contact material T2
Plastic material flammability reference UL94 V-2
Catalogue reference standard IEC; specific standard number not stated

The rated-voltage and withstand-voltage entries do not specify AC or DC. The withstand test duration is not stated. The conductor range is not divided into separate conductor classes.

Dimension

The catalogue gives the following L × W × H values without stating a measurement unit. The Catalogue P designation column retains the source label; it does not establish the number of electrically isolated circuits.

Model Catalogue P designation Catalogue L × W × H (unit not stated)
LT2-8 2P 39.3 × 43.3 × 15.4
LT4-8 4P 39.3 × 43.3 × 15.4
LT3-12 3P 39.3 × 63.3 × 15.4

Model Selection

LT2-8 and LT4-8 have identical listed body dimensions but different P designations. LT3-12 has a wider listed body. Model suffixes and wire-entry counts do not substitute for the required electrical connection arrangement.

Ordering Information

Provide the exact model, conductor type and cross-section, required colour where applicable, and quantity. Include the required connection arrangement in the enquiry.

Project details