304 Stainless Steel Waterproof Breathable Cable Gland
304 stainless steel cable gland combining cable entry sealing with a breathable design.
- Specified ingress protection: IP68.
- 10 configurations with model-specific cable ranges and metric threads.
- Minimum airflow requirements: 100β500 mL/min across the listed configurations, measured at 70 mbar.
Overview
The YOCL ELECTRIC 304 Stainless Steel Waterproof Breathable Cable Gland combines cable entry sealing with a breathable design. The supplied size table specifies cable diameter ranges, minimum airflow at a pressure differential of 70 mbar, metric entry threads and installation dimensions.
The body is 304 stainless steel. Select the configuration using its cable range, airflow requirement, thread length and wrench size.
Features
- Breathable cable entry: Model-specific minimum airflow values stated at 70 mbar.
- IP68 protection: As specified in the supplied product data.
- Material selection: 304 stainless steel body.
- Metric thread configurations: Cable clamping ranges and dimensions listed separately below.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product type | Waterproof breathable cable gland |
| Body material | 304 stainless steel |
| Colour / finish | Natural metal finish |
| Ingress protection | IP68 |
| Airflow test pressure differential | 70 mbar |
| Airflow specification | Minimum airflow varies by configuration; see table below |
| Entry thread | Metric, 1.5 mm pitch |
IP68 immersion depth and duration are not provided in the supplied data.
Dimension
Cable Range and Airflow
All cable dimensions are in millimetres. Airflow is the minimum value at 70 mbar.
| Configuration | Entry thread | Cable range (mm) | Minimum airflow (mL/min at 70 mbar) |
|---|---|---|---|
| M10Γ1.5/3β7 | M10Γ1.5 | 3β7 | β₯100 |
| M12Γ1.5/3β7 | M12Γ1.5 | 3β7 | β₯100 |
| M12Γ1.5/4β8 | M12Γ1.5 | 4β8 | β₯100 |
| M12Γ1.5/4β8 | M12Γ1.5 | 4β8 | β₯200 |
| M16Γ1.5/4β8 | M16Γ1.5 | 4β8 | β₯200 |
| M16Γ1.5/5β10 | M16Γ1.5 | 5β10 | β₯300 |
| M18Γ1.5/5β10 | M18Γ1.5 | 5β10 | β₯300 |
| M20Γ1.5/6β12 | M20Γ1.5 | 6β12 | β₯300 |
| M22Γ1.5/10β14 | M22Γ1.5 | 10β14 | β₯500 |
| M25Γ1.5/10β16 | M25Γ1.5 | 10β16 | β₯500 |
Installation Dimensions
AG is the nominal metric thread diameter; GL is the entry thread length. Wrench sizes are in millimetres.
| Configuration | Minimum airflow (mL/min at 70 mbar) | Thread diameter AG (mm) | Thread length GL (mm) | Wrench size (mm) |
|---|---|---|---|---|
| M10Γ1.5/3β7 | β₯100 | 10 | 6 | 14 |
| M12Γ1.5/3β7 | β₯100 | 12 | 6 | 14 |
| M12Γ1.5/4β8 | β₯100 | 12 | 7 | 17 |
| M12Γ1.5/4β8 | β₯200 | 12 | 7.5 | 18 |
| M16Γ1.5/4β8 | β₯200 | 16 | 7.5 | 18 |
| M16Γ1.5/5β10 | β₯300 | 16 | 7.5 | 22 |
| M18Γ1.5/5β10 | β₯300 | 18 | 8 | 22 |
| M20Γ1.5/6β12 | β₯300 | 20 | 8 | 22 |
| M22Γ1.5/10β14 | β₯500 | 22 | 8 | 27 |
| M25Γ1.5/10β16 | β₯500 | 25 | 9 | 27 |
M12Γ1.5/4β8 has two configurations: β₯100 mL/min with GL 7 mm and wrench size 17 mm; β₯200 mL/min with GL 7.5 mm and wrench size 18 mm. These are separate entries, not duplicate rows.
Overall body height H is shown in the reference drawing but is not tabulated; no H values are assigned here.
Ordering Information
Specify the body material, metric thread size, cable diameter range and required minimum airflow. Check the entry thread length and available wrench clearance against the enclosure.
For M12Γ1.5/4β8, include the airflow requirement and GL to distinguish the two configurations.