YOCL

IP67 Industrial Plugs

YOCL ELECTRIC IP67 industrial plugs for cable-end connections, with distinct housing designs and complete NM model selection tables.

  • Rated currents: 16 A, 32 A, 63 A and 125 A.
  • Contact arrangements: 2P+E, 3P+E and 3P+N+E.
  • 4h, 6h and selected 3h earth-contact layouts, depending on model.
  • Male cable plug with rear cable entry.
  • Select voltage, conductor capacity and dimensions by the full model code.
Inquire about this product

Overview

YOCL ELECTRIC IP67 industrial plugs are male cable plugs for industrial cable connections. This family brings together the actual 16 A, 32 A, 63 A and 125 A models listed below, with 2P+E, 3P+E and 3P+N+E contact arrangements. Each model has its own voltage, earth-contact clock position and housing design.

The front has projecting male contacts and a locking-ring mating design, with cable entry at the rear. The 16 / 32 A and 63 / 125 A body designs are separated in the model tables. Special 3h versions are included as named models, with their own contact position.

Features

  • IP67 protection rating for the listed models.
  • Male contacts with cable mounting rather than panel mounting.
  • Rated current choices: 16 A, 32 A, 63 A and 125 A; the actual combinations are defined by the model tables.
  • 2P+E, 3P+E and 3P+N+E versions are identified individually.
  • Earth-contact layouts: 4h, 6h and selected 3h, according to the named model.
  • Separate housing groups preserve each modelโ€™s conductor capacity and dimensional data.

Technical Specifications

Parameter Specification
Brand YOCL ELECTRIC
Product type Male cable plugs
Mounting Cable-mounted
Protection rating IP67
Rated currents 16 A, 32 A, 63 A and 125 A
Contact arrangements 2P+E (3 contacts); 3P+E (4 contacts); 3P+N+E (5 contacts)
Earth-contact positions 4h, 6h and selected 3h
Voltage configurations See the individual model rows; paired five-contact ratings are retained as listed.
Conductor capacities Model-specific values in mmยฒ; see the selection tables.
Housing designs See the separate model groups below.

Locking-ring housing design โ€” 16 / 32 A

Model Printed reference Current (A) Contacts Voltage (V) Clock Conductor capacity (mmยฒ) Body color
NM-0131-4 278 16 2P+E 110โ€“130 4h 1โ€“2.5 Yellow
NM-0231-4 290 32 2P+E 110โ€“130 4h 2.5โ€“6 Yellow
NM-0131 278 16 2P+E 220โ€“240 6h 1โ€“2.5 Blue
NM-0231 290 32 2P+E 220โ€“240 6h 2.5โ€“6 Blue
NM-0141 282 16 3P+E 380โ€“415 6h 1โ€“2.5 Red
NM-0241 294 32 3P+E 380โ€“415 6h 2.5โ€“6 Red
NM-0151 288 16 3P+N+E 220โ€“380 / 240โ€“415 6h 1โ€“2.5 Red
NM-0251 291 32 3P+N+E 220โ€“380 / 240โ€“415 6h 2.5โ€“6 Red

White rear-body locking design โ€” 16 / 32 A

Model Current (A) Contacts Voltage (V) Clock Conductor capacity (mmยฒ) Body color
NM-0132 16 2P+E 220โ€“240 6h 1โ€“2.5 Blue
NM-0232 32 2P+E 220โ€“240 6h 2.5โ€“6 Blue
NM-0142 16 3P+E 380โ€“415 6h 1โ€“2.5 Red
NM-0242 32 3P+E 380โ€“415 6h 2.5โ€“6 Red
NM-0152 16 3P+N+E 220โ€“380 / 240โ€“415 6h 1โ€“2.5 Red
NM-0252 32 3P+N+E 220โ€“380 / 240โ€“415 6h 2.5โ€“6 Red

Grey rear-body design โ€” 63 / 125 A

Model Current (A) Contacts Voltage (V) Clock Conductor capacity (mmยฒ) Body color
NM-0332 63 2P+E 220โ€“240 6h 6โ€“16 Blue
NM-0432 125 2P+E 220โ€“240 6h 16โ€“50 Blue
NM-0342 63 3P+E 380โ€“415 6h 6โ€“16 Red
NM-0442 125 3P+E 380โ€“415 6h 16โ€“50 Red
NM-0352 63 3P+N+E 220โ€“380 / 240โ€“415 6h 6โ€“16 Red
NM-0452 125 3P+N+E 220โ€“380 / 240โ€“415 6h 16โ€“50 Red

White rear-body design โ€” 63 / 125 A

Model Current (A) Contacts Voltage (V) Clock Conductor capacity (mmยฒ) Body color
NM-033 63 2P+E 220โ€“240 6h 6โ€“16 Blue
NM-043 125 2P+E 220โ€“240 6h 16โ€“50 Blue
NM-034 63 3P+E 380โ€“415 6h 6โ€“16 Red
NM-044 125 3P+E 380โ€“415 6h 16โ€“50 Red
NM-035 63 3P+N+E 220โ€“380 / 240โ€“415 6h 6โ€“16 Red
NM-045 125 3P+N+E 220โ€“380 / 240โ€“415 6h 16โ€“50 Red

Special 3h contact layout โ€” 16 / 32 A

These 3h models are distinct from the ordinary 6h models; the model suffix must be included when ordering.

Model Current (A) Contacts Voltage (V) Clock Conductor capacity (mmยฒ) Body color
NM-0142-3 16 3P+E 380โ€“415 3h โ€” Red
NM-0242-3 32 3P+E 380โ€“415 3h โ€” Red

Dimension

The symbols below reproduce each housing groupโ€™s dimensional table in millimetres. Letter meanings differ between drawings; a repeated symbol does not define one common dimension across all groups. Match the full model code and housing group before using a drawing.

Locking-ring housing design โ€” 16 / 32 A

Model Drawing/table dimensions (mm)
NM-0131-4 a = 138; b = 115; d = 70.2
NM-0231-4 a = 170; b = 141; d = 93.3
NM-0131 a = 138; b = 115; d = 70.2
NM-0231 a = 170; b = 141; d = 93.3
NM-0141 a = 144; b = 120.5; d = 78
NM-0241 a = 170; b = 141; d = 93.3
NM-0151 a = 144; b = 120.5; d = 87
NM-0251 a = 177; b = 148; d = 101

White rear-body locking design โ€” 16 / 32 A

Model Drawing/table dimensions (mm)
NM-0132 a = 127; b = 47; c = 6โ€“15; SW = 44
NM-0232 a = 158; b = 63; c = 10โ€“20; SW = 54
NM-0142 a = 133; b = 53; c = 6โ€“15; SW = 44
NM-0242 a = 158; b = 63; c = 10โ€“20; SW = 54
NM-0152 a = 140; b = 61; c = 6โ€“15; SW = 44
NM-0252 a = 165; b = 69; c = 10โ€“20; SW = 54

Grey rear-body design โ€” 63 / 125 A

Model Drawing/table dimensions (mm)
NM-0332 a = 250; b = 115; c = 23
NM-0432 a = 275; b = 128; c = 31
NM-0342 a = 250; b = 115; c = 23
NM-0442 a = 275; b = 128; c = 31
NM-0352 a = 250; b = 115; c = 23
NM-0452 a = 275; b = 128; c = 31

White rear-body design โ€” 63 / 125 A

Model Drawing/table dimensions (mm)
NM-033 a = 231.5; b = 110; c = 16โ€“38; ฯ† = 110
NM-043 a = 295; b = 123; c = 30โ€“64; ฯ† = 123
NM-034 a = 231.5; b = 110; c = 16โ€“38; ฯ† = 110
NM-044 a = 295; b = 123; c = 30โ€“64; ฯ† = 123
NM-035 a = 231.5; b = 110; c = 16โ€“38; ฯ† = 110
NM-045 a = 295; b = 123; c = 30โ€“64; ฯ† = 123

IP67 Industrial Plugs dimension drawing

IP67 Industrial Plugs dimension drawing

IP67 Industrial Plugs dimension drawing

IP67 Industrial Plugs dimension drawing

IP67 Industrial Plugs dimension drawing

Selection Guide

Choose a male cable plug for a cable-end connection. A panel-mounted or surface-mounted appliance inlet uses a fixed mounting arrangement and belongs to a different product family.

Select the current rating, contact arrangement, rated voltage, earth-contact clock position and IP rating together from one actual model row. Body color alone is insufficient: the special clock-position groups include different voltage/contact combinations from the ordinary groups.

Keep the complete suffix when selecting the housing version. Models that share an electrical rating may have different lengths, cable-entry dimensions or body shapes. Conductor capacity is a cross-sectional range in mmยฒ and must not be confused with a cable-entry dimension in mm.

For five-contact models, the table preserves the paired 220โ€“380 / 240โ€“415 V notation. It does not create an additional arbitrary voltage combination. A dash in the capacity column means that the particular row supplies no confirmed value.

Ordering Information

When enquiring about YOCL ELECTRIC IP67 industrial plugs, provide the full model code, quantity, current rating, contact arrangement, rated voltage, clock position and the required housing design. Include the conductor cross-section and cable outside diameter so that the cable entry and terminal range can be checked for that specific model.

Printed secondary references identify the catalogue entries where shown; they do not create extra model options or replace the full NM model code.

Project details

Fields marked * are required.