IP67 Industrial Plugs
YOCL ELECTRIC IP67 industrial plugs for cable-end connections, with distinct housing designs and complete NM model selection tables.
- Rated currents: 16 A, 32 A, 63 A and 125 A.
- Contact arrangements: 2P+E, 3P+E and 3P+N+E.
- 4h, 6h and selected 3h earth-contact layouts, depending on model.
- Male cable plug with rear cable entry.
- Select voltage, conductor capacity and dimensions by the full model code.
Overview
YOCL ELECTRIC IP67 industrial plugs are male cable plugs for industrial cable connections. This family brings together the actual 16 A, 32 A, 63 A and 125 A models listed below, with 2P+E, 3P+E and 3P+N+E contact arrangements. Each model has its own voltage, earth-contact clock position and housing design.
The front has projecting male contacts and a locking-ring mating design, with cable entry at the rear. The 16 / 32 A and 63 / 125 A body designs are separated in the model tables. Special 3h versions are included as named models, with their own contact position.
Features
- IP67 protection rating for the listed models.
- Male contacts with cable mounting rather than panel mounting.
- Rated current choices: 16 A, 32 A, 63 A and 125 A; the actual combinations are defined by the model tables.
- 2P+E, 3P+E and 3P+N+E versions are identified individually.
- Earth-contact layouts: 4h, 6h and selected 3h, according to the named model.
- Separate housing groups preserve each modelβs conductor capacity and dimensional data.
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | YOCL ELECTRIC |
| Product type | Male cable plugs |
| Mounting | Cable-mounted |
| Protection rating | IP67 |
| Rated currents | 16 A, 32 A, 63 A and 125 A |
| Contact arrangements | 2P+E (3 contacts); 3P+E (4 contacts); 3P+N+E (5 contacts) |
| Earth-contact positions | 4h, 6h and selected 3h |
| Voltage configurations | See the individual model rows; paired five-contact ratings are retained as listed. |
| Conductor capacities | Model-specific values in mmΒ²; see the selection tables. |
| Housing designs | See the separate model groups below. |
Locking-ring housing design β 16 / 32 A
| Model | Printed reference | Current (A) | Contacts | Voltage (V) | Clock | Conductor capacity (mmΒ²) | Body color |
|---|---|---|---|---|---|---|---|
| NM-0131-4 | 278 | 16 | 2P+E | 110β130 | 4h | 1β2.5 | Yellow |
| NM-0231-4 | 290 | 32 | 2P+E | 110β130 | 4h | 2.5β6 | Yellow |
| NM-0131 | 278 | 16 | 2P+E | 220β240 | 6h | 1β2.5 | Blue |
| NM-0231 | 290 | 32 | 2P+E | 220β240 | 6h | 2.5β6 | Blue |
| NM-0141 | 282 | 16 | 3P+E | 380β415 | 6h | 1β2.5 | Red |
| NM-0241 | 294 | 32 | 3P+E | 380β415 | 6h | 2.5β6 | Red |
| NM-0151 | 288 | 16 | 3P+N+E | 220β380 / 240β415 | 6h | 1β2.5 | Red |
| NM-0251 | 291 | 32 | 3P+N+E | 220β380 / 240β415 | 6h | 2.5β6 | Red |
White rear-body locking design β 16 / 32 A
| Model | Current (A) | Contacts | Voltage (V) | Clock | Conductor capacity (mmΒ²) | Body color |
|---|---|---|---|---|---|---|
| NM-0132 | 16 | 2P+E | 220β240 | 6h | 1β2.5 | Blue |
| NM-0232 | 32 | 2P+E | 220β240 | 6h | 2.5β6 | Blue |
| NM-0142 | 16 | 3P+E | 380β415 | 6h | 1β2.5 | Red |
| NM-0242 | 32 | 3P+E | 380β415 | 6h | 2.5β6 | Red |
| NM-0152 | 16 | 3P+N+E | 220β380 / 240β415 | 6h | 1β2.5 | Red |
| NM-0252 | 32 | 3P+N+E | 220β380 / 240β415 | 6h | 2.5β6 | Red |
Grey rear-body design β 63 / 125 A
| Model | Current (A) | Contacts | Voltage (V) | Clock | Conductor capacity (mmΒ²) | Body color |
|---|---|---|---|---|---|---|
| NM-0332 | 63 | 2P+E | 220β240 | 6h | 6β16 | Blue |
| NM-0432 | 125 | 2P+E | 220β240 | 6h | 16β50 | Blue |
| NM-0342 | 63 | 3P+E | 380β415 | 6h | 6β16 | Red |
| NM-0442 | 125 | 3P+E | 380β415 | 6h | 16β50 | Red |
| NM-0352 | 63 | 3P+N+E | 220β380 / 240β415 | 6h | 6β16 | Red |
| NM-0452 | 125 | 3P+N+E | 220β380 / 240β415 | 6h | 16β50 | Red |
White rear-body design β 63 / 125 A
| Model | Current (A) | Contacts | Voltage (V) | Clock | Conductor capacity (mmΒ²) | Body color |
|---|---|---|---|---|---|---|
| NM-033 | 63 | 2P+E | 220β240 | 6h | 6β16 | Blue |
| NM-043 | 125 | 2P+E | 220β240 | 6h | 16β50 | Blue |
| NM-034 | 63 | 3P+E | 380β415 | 6h | 6β16 | Red |
| NM-044 | 125 | 3P+E | 380β415 | 6h | 16β50 | Red |
| NM-035 | 63 | 3P+N+E | 220β380 / 240β415 | 6h | 6β16 | Red |
| NM-045 | 125 | 3P+N+E | 220β380 / 240β415 | 6h | 16β50 | Red |
Special 3h contact layout β 16 / 32 A
These 3h models are distinct from the ordinary 6h models; the model suffix must be included when ordering.
| Model | Current (A) | Contacts | Voltage (V) | Clock | Conductor capacity (mmΒ²) | Body color |
|---|---|---|---|---|---|---|
| NM-0142-3 | 16 | 3P+E | 380β415 | 3h | β | Red |
| NM-0242-3 | 32 | 3P+E | 380β415 | 3h | β | Red |
Dimension
The symbols below reproduce each housing groupβs dimensional table in millimetres. Letter meanings differ between drawings; a repeated symbol does not define one common dimension across all groups. Match the full model code and housing group before using a drawing.
Locking-ring housing design β 16 / 32 A
| Model | Drawing/table dimensions (mm) |
|---|---|
| NM-0131-4 | a = 138; b = 115; d = 70.2 |
| NM-0231-4 | a = 170; b = 141; d = 93.3 |
| NM-0131 | a = 138; b = 115; d = 70.2 |
| NM-0231 | a = 170; b = 141; d = 93.3 |
| NM-0141 | a = 144; b = 120.5; d = 78 |
| NM-0241 | a = 170; b = 141; d = 93.3 |
| NM-0151 | a = 144; b = 120.5; d = 87 |
| NM-0251 | a = 177; b = 148; d = 101 |
White rear-body locking design β 16 / 32 A
| Model | Drawing/table dimensions (mm) |
|---|---|
| NM-0132 | a = 127; b = 47; c = 6β15; SW = 44 |
| NM-0232 | a = 158; b = 63; c = 10β20; SW = 54 |
| NM-0142 | a = 133; b = 53; c = 6β15; SW = 44 |
| NM-0242 | a = 158; b = 63; c = 10β20; SW = 54 |
| NM-0152 | a = 140; b = 61; c = 6β15; SW = 44 |
| NM-0252 | a = 165; b = 69; c = 10β20; SW = 54 |
Grey rear-body design β 63 / 125 A
| Model | Drawing/table dimensions (mm) |
|---|---|
| NM-0332 | a = 250; b = 115; c = 23 |
| NM-0432 | a = 275; b = 128; c = 31 |
| NM-0342 | a = 250; b = 115; c = 23 |
| NM-0442 | a = 275; b = 128; c = 31 |
| NM-0352 | a = 250; b = 115; c = 23 |
| NM-0452 | a = 275; b = 128; c = 31 |
White rear-body design β 63 / 125 A
| Model | Drawing/table dimensions (mm) |
|---|---|
| NM-033 | a = 231.5; b = 110; c = 16β38; Ο = 110 |
| NM-043 | a = 295; b = 123; c = 30β64; Ο = 123 |
| NM-034 | a = 231.5; b = 110; c = 16β38; Ο = 110 |
| NM-044 | a = 295; b = 123; c = 30β64; Ο = 123 |
| NM-035 | a = 231.5; b = 110; c = 16β38; Ο = 110 |
| NM-045 | a = 295; b = 123; c = 30β64; Ο = 123 |





Selection Guide
Choose a male cable plug for a cable-end connection. A panel-mounted or surface-mounted appliance inlet uses a fixed mounting arrangement and belongs to a different product family.
Select the current rating, contact arrangement, rated voltage, earth-contact clock position and IP rating together from one actual model row. Body color alone is insufficient: the special clock-position groups include different voltage/contact combinations from the ordinary groups.
Keep the complete suffix when selecting the housing version. Models that share an electrical rating may have different lengths, cable-entry dimensions or body shapes. Conductor capacity is a cross-sectional range in mmΒ² and must not be confused with a cable-entry dimension in mm.
For five-contact models, the table preserves the paired 220β380 / 240β415 V notation. It does not create an additional arbitrary voltage combination. A dash in the capacity column means that the particular row supplies no confirmed value.
Ordering Information
When enquiring about YOCL ELECTRIC IP67 industrial plugs, provide the full model code, quantity, current rating, contact arrangement, rated voltage, clock position and the required housing design. Include the conductor cross-section and cable outside diameter so that the cable entry and terminal range can be checked for that specific model.