YOCL

LT-4FFD-C Series Lever Terminal Blocks

YOCL ELECTRIC LT-4FFD-C series lever terminal blocks use the broader and taller base format shown for the C-suffixed models.

  • 450 V rated voltage; 32 A rated current
  • 0.5–4 mm² listed conductor cross-section
  • 11–12 mm stripping length
  • 8 listed model options
  • Broader and taller C body format
Inquire about this product

Overview

YOCL ELECTRIC LT-4FFD-C series lever terminal blocks use the broader and taller base format shown for the C-suffixed models. The eight listed options share 450 V, 32 A ratings and a 0.5–4 mm² conductor range.

Features

  • C body versions with a wider and taller base envelope.
  • Eight listed models: 2C, 3C, 4C, 5C, 6C, 8C, 10C and 12C.
  • 450 V rated voltage and 32 A rated current.
  • PA plastic parts and an 11–12 mm stripping length.

Technical Specifications

Parameter Specification
Models LT-4FFD-2C, LT-4FFD-3C, LT-4FFD-4C, LT-4FFD-5C, LT-4FFD-6C, LT-4FFD-8C, LT-4FFD-10C, LT-4FFD-12C
Rated voltage 450 V
Rated current 32 A
Conductor cross-section 0.5–4 mm²
Listed withstand voltage 4 kV
Ambient temperature −40 °C to +105 °C
Stripping length 11–12 mm
Plastic parts PA
Spring material S301
Contact material T2
Plastic material flammability reference UL94 V-2
Catalogue reference standard IEC; specific standard number not stated

The rated-voltage and withstand-voltage entries do not specify AC or DC. The withstand test duration is not stated. The conductor range is not divided into separate conductor classes.

Dimension

The catalogue gives the following L × W × H values without stating a measurement unit. The Catalogue P designation column retains the source label; it does not establish the number of electrically isolated circuits.

Model Catalogue P designation Catalogue L × W × H (unit not stated)
LT-4FFD-2C 2P 49.6 × 33 × 26
LT-4FFD-3C 3P 49.6 × 39 × 26
LT-4FFD-4C 4P 49.6 × 45 × 26
LT-4FFD-5C 5P 49.6 × 51 × 26
LT-4FFD-6C 6P 49.6 × 57 × 26
LT-4FFD-8C 8P 49.6 × 69 × 26
LT-4FFD-10C 10P 49.6 × 81 × 26
LT-4FFD-12C 12P 49.6 × 93 × 26

Model Selection

Use the exact C-suffixed model and its 49.6 × W × 26 dimensional profile. The C suffix is not defined as a particular rail interface in the supplied data. The reference illustrations use several lever colours, without a model-specific guaranteed colour arrangement.

Ordering Information

Provide the exact model, conductor type and cross-section, required colour where applicable, and quantity. Include the required connection arrangement and mounting interface in the enquiry.

Project details

Fields marked * are required.

Your details will be used to respond to your enquiry. Privacy notice