YOCL

IP44 Industrial Plugs

YOCL ELECTRIC IP44 industrial plugs for cable-end connections, with distinct housing designs and complete NM model selection tables.

  • Rated currents: 16 A and 32 A.
  • Contact arrangements: 2P+E, 3P+E and 3P+N+E.
  • 4h, 6h and selected 9h earth-contact layouts, depending on model.
  • Male cable plug with rear cable entry.
  • Select voltage, conductor capacity and dimensions by the full model code.
Inquire about this product

Overview

YOCL ELECTRIC IP44 industrial plugs are male cable plugs for industrial cable connections. This family brings together the actual 16 A and 32 A models listed below, with 2P+E, 3P+E and 3P+N+E contact arrangements. Each model has its own voltage, earth-contact clock position and housing design.

The front has projecting male contacts and the rear accepts a cable. H-design, K-design and white rear-body versions provide distinct housings within one product family. The special 9h versions are listed separately from ordinary 4h and 6h models.

Features

  • IP44 protection rating for the listed models.
  • Male contacts with cable mounting rather than panel mounting.
  • Rated current choices: 16 A and 32 A; the actual combinations are defined by the model tables.
  • 2P+E, 3P+E and 3P+N+E versions are identified individually.
  • Earth-contact layouts: 4h, 6h and selected 9h, according to the named model.
  • Separate housing groups preserve each modelโ€™s conductor capacity and dimensional data.

Technical Specifications

Parameter Specification
Brand YOCL ELECTRIC
Product type Male cable plugs
Mounting Cable-mounted
Protection rating IP44
Rated currents 16 A and 32 A
Contact arrangements 2P+E (3 contacts); 3P+E (4 contacts); 3P+N+E (5 contacts)
Earth-contact positions 4h, 6h and selected 9h
Voltage configurations See the individual model rows; paired five-contact ratings are retained as listed.
Conductor capacities Model-specific values in mmยฒ; see the selection tables.
Housing designs See the separate model groups below.

H housing design โ€” 16 / 32 A

Model Printed reference Current (A) Contacts Voltage (V) Clock Conductor capacity (mmยฒ) Body color
NM-013H-4 248 16 2P+E 110โ€“130 4h 1โ€“2.5 Yellow
NM-023H-4 260 32 2P+E 110โ€“130 4h 2.5โ€“6 Yellow
NM-013H 248 16 2P+E 220โ€“240 6h 1โ€“2.5 Blue
NM-023H 260 32 2P+E 220โ€“240 6h 2.5โ€“6 Blue
NM-014H 252 16 3P+E 380โ€“415 6h 1โ€“2.5 Red
NM-024H 264 32 3P+E 380โ€“415 6h 2.5โ€“6 Red
NM-015H NM3 16 3P+N+E 220โ€“380 / 240โ€“415 6h 1โ€“2.5 Red
NM-025H NM4 32 3P+N+E 220โ€“380 / 240โ€“415 6h 2.5โ€“6 Red

K housing design โ€” 16 / 32 A

Model Current (A) Contacts Voltage (V) Clock Conductor capacity (mmยฒ) Body color
NM-013K-4 16 2P+E 110โ€“130 4h 1โ€“2.5 Yellow
NM-023K-4 32 2P+E 110โ€“130 4h 2.5โ€“6 Yellow
NM-013K 16 2P+E 220โ€“240 6h 1โ€“2.5 Blue
NM-023K 32 2P+E 220โ€“240 6h 2.5โ€“6 Blue
NM-014K 16 3P+E 380โ€“415 6h 1โ€“2.5 Red
NM-024K 32 3P+E 380โ€“415 6h 2.5โ€“6 Red
NM-015K 16 3P+N+E 220โ€“380 / 240โ€“415 6h 1โ€“2.5 Red
NM-025K 32 3P+N+E 220โ€“380 / 240โ€“415 6h 2.5โ€“6 Red

White rear-body designs โ€” 16 / 32 A

Model Current (A) Contacts Voltage (V) Clock Conductor capacity (mmยฒ) Body color
NM-013-4 16 2P+E 110โ€“130 4h 1โ€“2.5 Yellow
NM-023-4 32 2P+E 110โ€“130 4h 2.5โ€“6 Yellow
NM-013L 16 2P+E 220โ€“240 6h 1โ€“2.5 Blue
NM-023L 32 2P+E 220โ€“240 6h 2.5โ€“6 Blue
NM-013 16 2P+E 220โ€“240 6h 1โ€“2.5 Blue
NM-023 32 2P+E 220โ€“240 6h 2.5โ€“6 Blue
NM-014 16 3P+E 380โ€“415 6h 1โ€“2.5 Red
NM-024 32 3P+E 380โ€“415 6h 2.5โ€“6 Red
NM-015 16 3P+N+E 220โ€“380 / 240โ€“415 6h 1โ€“2.5 Red
NM-025 32 3P+N+E 220โ€“380 / 240โ€“415 6h 2.5โ€“6 Red

Special 9h contact layouts โ€” 16 / 32 A

These 9h models use the particular voltage and contact layouts shown below. Their conductor capacities and dimensions are not extended from the ordinary models.

Model Current (A) Contacts Voltage (V) Clock Conductor capacity (mmยฒ) Body color
NM-013L-9 16 2P+E 380โ€“415 9h โ€” Red
NM-023L-9 32 2P+E 380โ€“415 9h โ€” Red
NM-115L-9 16 3P+N+E 220โ€“240 9h โ€” Blue
NM-025L-9 32 3P+N+E 220โ€“240 9h โ€” Blue
NM-014L-9 16 3P+E 220โ€“240 9h โ€” Blue
NM-024L-9 32 3P+E 220โ€“240 9h โ€” Blue

Dimension

The symbols below reproduce each housing groupโ€™s dimensional table in millimetres. Letter meanings differ between drawings; a repeated symbol does not define one common dimension across all groups. Match the full model code and housing group before using a drawing.

H housing design โ€” 16 / 32 A

Model Drawing/table dimensions (mm)
NM-013H-4 a = 140; b = 116; c = 43.5; d = 38.5
NM-023H-4 a = 173; b = 144; c = 57; d = 51
NM-013H a = 140; b = 116; c = 43.5; d = 38.5
NM-023H a = 173; b = 144; c = 57; d = 51
NM-014H a = 140; b = 116; c = 49.5; d = 43.8
NM-024H a = 173; b = 144; c = 57; d = 51
NM-015H a = 140; b = 121; c = 56; d = 50
NM-025H a = 173; b = 144; c = 63.3; d = 56.5

K housing design โ€” 16 / 32 A

Model Drawing/table dimensions (mm)
NM-013K-4 a = 127; b = 87; c = 47; d = 6โ€“15; SW = 44
NM-023K-4 a = 158; b = 105; c = 63; d = 10โ€“20; SW = 54
NM-013K a = 127; b = 87; c = 47; d = 6โ€“15; SW = 44
NM-023K a = 158; b = 105; c = 63; d = 10โ€“20; SW = 54
NM-014K a = 133; b = 97; c = 53; d = 6โ€“15; SW = 44
NM-024K a = 158; b = 105; c = 63; d = 10โ€“20; SW = 54
NM-015K a = 140; b = 105; c = 61; d = 6โ€“15; SW = 44
NM-025K a = 165; b = 121; c = 70; d = 10โ€“20; SW = 54

White rear-body designs โ€” 16 / 32 A

Model Drawing/table dimensions (mm)
NM-013-4 a = 122; b = 57; c = 50; ฯ† = 6
NM-023-4 a = 141; b = 77; c = 64; ฯ† = 8
NM-013L a = 122; b = 57; c = 50; ฯ† = 6
NM-023L a = 141; b = 77; c = 64; ฯ† = 8
NM-013 a = 122; b = 57; c = 50; ฯ† = 6
NM-023 a = 141; b = 77; c = 64; ฯ† = 8
NM-014 a = 122; b = 64; c = 50; ฯ† = 6
NM-024 a = 141; b = 77; c = 64; ฯ† = 8
NM-015 a = 130; b = 75; c = 64; ฯ† = 8
NM-025 a = 144; b = 87; c = 70; ฯ† = 8

IP44 Industrial Plugs dimension drawing

IP44 Industrial Plugs dimension drawing

IP44 Industrial Plugs dimension drawing

IP44 Industrial Plugs dimension drawing

Selection Guide

Choose a male cable plug for a cable-end connection. A panel-mounted or surface-mounted appliance inlet uses a fixed mounting arrangement and belongs to a different product family.

Select the current rating, contact arrangement, rated voltage, earth-contact clock position and IP rating together from one actual model row. Body color alone is insufficient: the special clock-position groups include different voltage/contact combinations from the ordinary groups.

Keep the complete suffix when selecting the housing version. Models that share an electrical rating may have different lengths, cable-entry dimensions or body shapes. Conductor capacity is a cross-sectional range in mmยฒ and must not be confused with a cable-entry dimension in mm.

For five-contact models, the table preserves the paired 220โ€“380 / 240โ€“415 V notation. It does not create an additional arbitrary voltage combination. A dash in the capacity column means that the particular row supplies no confirmed value.

Ordering Information

When enquiring about YOCL ELECTRIC IP44 industrial plugs, provide the full model code, quantity, current rating, contact arrangement, rated voltage, clock position and the required housing design. Include the conductor cross-section and cable outside diameter so that the cable entry and terminal range can be checked for that specific model.

Printed secondary references identify the catalogue entries where shown; they do not create extra model options or replace the full NM model code.

Project details

Fields marked * are required.

Your details will be used to respond to your enquiry. Privacy notice